TRIO-PS/3AC/24DC/40
Delivery time:8-12 weeks
AC operation | |
Nominal input voltage range | 3x 400 V AC ... 500 V AC |
Input voltage range | 3x 320 V AC ... 575 V AC |
2x 360 V AC ... 575 V AC (for 2-phase operation) | |
Input voltage range AC | 3x 320 V AC ... 575 V AC |
2x 360 V AC ... 575 V AC (for 2-phase operation) | |
Voltage type of supply voltage | AC |
Inrush current | < 20 A |
Inrush current integral (I2t) | 1.3 A2s |
AC frequency range | 45 Hz ... 65 Hz |
Mains buffering time | > 16 ms (400 V AC) |
> 20 ms (480 V AC) | |
Current consumption | 3x 2 A (400 V AC) |
3x 1.6 A (480 V AC) | |
Nominal power consumption | 1387 VA |
Protective circuit | Transient surge protection; Varistor |
Power factor (cos phi) | 0.76 |
Typical response time | < 1 s |
Permissible backup fuse | B10 B16 |
Recommended breaker for input protection | 6 A ... 16 A (Characteristics B, C, D, K) |
Discharge current to PE | < 3.5 mA |
Efficiency | > 91.5 % (at 400 V AC and nominal values) |
Output characteristic | U/I |
Nominal output voltage | 24 V DC ±1 % |
Setting range of the output voltage (USet) | 22.5 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) | 40 A (-25 °C ... 55 °C) |
Derating | 55 °C ... 70 °C (2.5%/K) |
Feedback voltage resistance | 35 V DC |
Protection against overvoltage at the output (OVP) | < 35 V DC |
Max. capacitive load | unlimited |
Active current limitation | Approx. 48 A |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
< 2 % (change in load, dynamic 10 % ... 90 %) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 20 mVPP |
Output power | 960 W |
Peak switching voltages nominal load | < 40 mVPP |
Maximum no-load power dissipation | 16 W |
Power loss nominal load max. | 91 W |
Rise time | < 2 ms (UOUT (10 % ... 90 %)) |
Connection in parallel | yes, for redundancy and increased capacity |
Connection in series | yes |
Input | |
Connection method | Screw connection |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 22 |
Conductor cross section AWG max. | 10 |
Stripping length | 8 mm |
Screw thread | M3 |
Tightening torque, min | 0.5 Nm |
Tightening torque max | 0.6 Nm |
Output | |
Connection method | Screw connection |
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 10 mm² |
Conductor cross section AWG min. | 8 |
Conductor cross section AWG max. | 6 |
Stripping length | 10 mm |
Screw thread | M4 |
Tightening torque, min | 1.2 Nm |
Tightening torque max | 1.5 Nm |